Tel:+86-595-22656925
Tel:+86-595-22656926
Fax:+86-595-22656927
Add:Qixiang Building, Tangxi Industrial Zone, Luojiang District,Quanzhou 362011, Fujian, China
E-mail: ken6833@qxdz.cn
Test item | Unit | Specification | Remark | ||
uplink | downlink | ||||
Frequency Range | GSM + DCS + WCDMA | MHz | 890~915 1710~1785 1920~1980 | 935~960 1805~1880 2110~2170 | |
Rated power | dBm | ≤23 | ≤23 | ||
ALC control range | dB | ≥20 | ≥20 | Output varies ±1.5 or close and resume | |
Gain | dB | ≥60 | ≥70 | ||
Max input power | dBm | ≤-35 | ≤-45 | ||
Inter-modulation Attenuation | CDMA800band | dBm | ≤-15 | Dual-band Spacing: 1.23MHz | |
GSM900band | dBm | ≤-40 | Dual-band Spacing: 0.6MHz | ||
DCS1800band | dBm | ≤-40 | Dual-band Spacing: 0.6MHz | ||
PCS1900band | dBm | ≤-40 | Dual-band Spacing: 0.6MHz | ||
3G/UMTS/WCDMAband | dBm | ≤-40 | Dual-band Spacing: 5MHz | ||
In-band Fluctuation | dB | ≤5.0 | |||
Gain adjustment | adjustment range | dB | 31/1dBstepping | ||
adjustment error | dB | ≤±1.5 | |||
Noise Figure | dB | ≤6 | Max gain | ||
Port VSWR | ≤2.0 | Electrify test | |||
Group delay | μs | ≤5 | |||
Voltage | DC | V | 9 | ||
AC | V | 110~220 | |||
Working current (DC) | A | 5 | |||
Working temperature | ℃ | -25~+55 | |||
Impedance | Ω | 50 | |||
RF connector | NK |